Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Rev. bras. ginecol. obstet ; 42(11): 697-704, Nov. 2020. tab, graf
Article in English | LILACS | ID: biblio-1144172

ABSTRACT

Abstract Objective: Recent observations support the hypothesis that an imbalance between angiogenic factors has a fundamental role in the pathogenesis of pre-eclampsia and is responsible for the clinical manifestations of the disease. The goal of the present study was to evaluate the sensitivity, specificity, and the best accuracy level of Soluble fms-like tyrosine kinase-1 (sFlt-1), placental growth factor (PlGF), and sFlt-1/PlGF ratio in maternal serum and protein/creatinine ratio in urine sample to define the best cutoff point of these tests to discriminate between the patients with gestational hypertension and the patients with pre-eclampsia, to evaluate the possibility of using them as diagnostic methods. Methods: A prospective longitudinal study was performed, and blood samples were collected from 95 pregnant patients with hypertension to measure serum concentrations of biomarkers sFlt-1 and PlGF. Urine samples were collected for protein screening. Significance was set as p < 0.05. Results: The sFlt-1/PlGF ratio demonstrated a sensitivity of 57.5% and a specificity of 60% using 50.4 as a cutoff point. The test that showed the best accuracy in the diagnosis of pre-eclampsia was protein/creatinine ratio, with a sensitivity of 78.9% and a specificity of 70% using 0.4 as a cutoff point and showing an area under the receiver operating characteristic curve of 0.80 (p < 0.001). Conclusion: No studied laboratory test proved to be fairly accurate for the diagnosis of pre-eclampsia, except for the protein/creatinine ratio. The evidence is insufficient to recommend biomarkers sFlt-1 and PlGF to be used for the diagnosis of pre-eclampsia.


Resumo Objetivo: Pesquisas recentes sustentam a hipótese de que um desequilíbrio entre fatores angiogênicos desempenhe um papel fundamental na patogênese da pré-eclâmpsia e seja responsável pelas manifestações clínicas da doença. O objetivo do presente estudo foi avaliar a sensibilidade, a especificidade e o nível de melhor acurácia do Fator semelhante a tirosina quinase 1 (sFlt-1), Fator de crescimento placentário (PlGF), e relação sFlt-1/PlGF no soro materno e relação proteína/creatinina em amostra de urina e definir o melhor ponto de corte desses testes para distinguir pacientes com hipertensão gestacional daquelas com pré-eclâmpsia, a fim de avaliar a possibilidade de utilizá-los como métodos diagnósticos. Métodos: Foi realizado um estudo prospectivo longitudinal e foram coletadas amostras de sangue de 95 gestantes com hipertensão arterial para dosar as concentrações séricas dos biomarcadores sFlt-1 e PlGF. Amostras de urina foram coletadas para pesquisa de proteinúria. Foram consideradas significativas as diferenças com p < 0,05. Resultados: A relação sFlt-1/PlGF demonstrou sensibilidade de 57,5% e especificidade de 60% utilizando 50,4 como ponto de corte. O teste que apresentou a melhor acurácia no diagnóstico de pré-eclâmpsia foi a relação proteína/creatinina, com sensibilidade de 78,9% e especificidade de 70%, utilizando 0,4 como ponto de corte e demostrando uma área sob a curva receiver operating characteristic (ROC, na sigla em inglês) de 0,80 (p < 0,001). Conclusão: Nenhum método de rastreamento isolado se mostrou com boa acurácia para o diagnóstico de pré-eclâmpsia, exceto a relação proteína/creatinina. As evidências são insuficientes para recomendar os biomarcadores sFlt-1 e PlGF como diagnóstico de pré-eclâmpsia.


Subject(s)
Humans , Female , Pregnancy , Adult , Pre-Eclampsia/epidemiology , Prenatal Care , Vascular Endothelial Growth Factor Receptor-1/blood , Placenta Growth Factor/blood , Pre-Eclampsia/etiology , Pre-Eclampsia/blood , Biomarkers/blood , Predictive Value of Tests , Sensitivity and Specificity
3.
Rev. bras. ginecol. obstet ; 41(2): 97-101, Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-1003529

ABSTRACT

Abstract Objective To analyze the prescription of antimicrobial agents for pregnant women admitted into the obstetrics service who presented with acute pyelonephritis. Methods Three cross-sectional studies were performed comparing the prescription of antimicrobials for pyelonephritis in pregnant women in the time periods evaluated (2010-2011: 99 patients evaluated; 2013: 116 patients evaluated; 2015: 107 patients evaluated), at the Hospital Fêmina, Porto Alegre, in the state of Rio Grande do Sul, Brazil. The analysis was performed before and after the promotion of an institutional protocol for the treatment of pyelonephritis during pregnancy, and on a third occasion after the introduction of a smartphone-based mobile educational tool. Results The evaluation of the prescribing physicians and the adequacy of the prescriptions between the different periods studied revealed a significant increase in appropriate conduct for the choice of antimicrobial (2010: 83.8%; 2013: 95.7%; and 2015: 100%), route of administration (2010: 97%; 2013: 100%; and 2015: 100%), and interval (2010: 91.9%; 2013: 95.7%; and 2015: 100%), following the introduction of the protocol, and again after the implementation of the softwareapplicationwithorientationsontheantimicrobial treatment. Conclusion The use of specific mobile applications should be encouraged to attain a better quality and accuracy in prescriptions and to include strategies that not only reduce the risk of negative outcomes, but also improve the quality of care and treatment for maintaining the health both of the mother and of the baby.


Resumo Objetivo Analisar a prescrição de antimicrobianos para gestantes admitidas no serviço de obstetrícia que apresentaram pielonefrite aguda. Métodos Foram realizados três estudos transversais comparando a prescrição de antimicrobianos para pielonefrite em gestantes nos períodos avaliados (2010-2011: 99 indivíduos avaliados; 2013: 116 indivíduos avaliados; 2015: 107 indivíduos avaliados), no Hospital Fêmina, Porto Alegre, RS, Brasil. A análise foi realizada antes e após a promoção de um protocolo institucional para o tratamento da pielonefrite durante a gravidez e, em uma terceira ocasião, após a introdução de uma ferramenta educacional móvel para uso por smartphone. Resultados A avaliação das prescrições médicas e a adequação das prescrições entre os diferentes períodos estudados revelaram um aumento significativo na conduta adequada para a escolha do antimicrobiano (2010: 83,8%; 2013: 95,7%; e 2015: 100%), via de administração (2010: 97%; 2013: 100%; e 2015: 100%) e intervalo (2010: 91,9%; 2013: 95,7%; e 2015: 100%), após a introdução do protocolo, e novamente após a implementação do aplicativo com orientações sobre tratamento antimicrobiano. Conclusão O uso de aplicativos móveis específicos deve ser incentivado para obter melhor qualidade e precisão nas prescrições e incluir estratégias que não apenas reduzam o risco de resultados negativos, mas que também melhorem a qualidade dos cuidados e do tratamento para manter a saúde conjunta da mãe e do bebê.


Subject(s)
Humans , Female , Pregnancy , Pregnancy Complications, Infectious/drug therapy , Pyelonephritis/drug therapy , Mobile Applications , Anti-Bacterial Agents/therapeutic use , Obstetrics/education , Drug Prescriptions/standards , Quality of Health Care , Urinary Tract Infections/drug therapy , Practice Patterns, Physicians'/standards , Brazil , Clinical Protocols , Acute Disease , Cross-Sectional Studies , Retrospective Studies , Cell Phone , Education, Medical/methods , Hospitalization
4.
Rev. bras. ginecol. obstet ; 41(1): 11-16, Jan. 2019. tab
Article in English | LILACS | ID: biblio-1003514

ABSTRACT

Abstract Objective To evaluate the accuracy of the diagnosis of fetal heart diseases obtained through ultrasound examinations performed during the prenatal period compared with the postnatal evaluation. Methods A retrospective cohort study with 96 pregnant women who were attended at the Echocardiography Service and whose deliveries occurred at the Complexo Hospitalar Santa Casa de Porto Alegre, in the state of Rio Grande do Sul, Brazil. Risk factor assessment plus sensitivity and specificity analysis were used, comparing the accuracy of the screening for congenital heart disease by means of obstetrical ultrasound and morphological evaluation and fetal echocardiography, considering p < 0.05 as significant. The present study was approved by the Research Ethics Committee of the Institution. Results The analysis of risk factors shows that 31.3% of the fetuses with congenital heart disease could be identified by anamnesis. The antepartum echocardiography demonstrated a sensitivity of 97.7%, a specificity of 88.9%, and accuracy of 93% in the diagnosis of congenital heart disease. A sensitivity of 29.3% was found for the obstetric ultrasound, of 54.3% for themorphological ultrasound, and of 97.7% for the fetal echocardiography. The fetal echocardiography detected fetal heart disease in 67.7% of the cases, the morphological ultrasound in 16.7%, and the obstetric ultrasound in 11.5% of the cases. Conclusion There is a high proportion of congenital heart disease in pregnancies with no risk factors for this outcome. Faced with the disappointing results of obstetric ultrasound for the detection of congenital heart diseases and the current unfeasibility of universal screening of congenital heart diseases through fetal echocardiography, the importance of the fetal morphological ultrasound and its performance by qualified professionals is reinforced for a more appropriate management of these pregnancies.


Resumo Objetivo Avaliar a acurácia do diagnóstico de cardiopatias congênitas obtidos por meio das ecografias realizadas durante o pré-natal comparativamente à avaliação pósnatal. Métodos Estudo de coorte retrospectivo com 96 gestantes atendidas no Serviço de Ecocardiografia cujos partos ocorreram no Complexo Hospitalar Santa Casa de Porto Alegre, RS, Brasil. Utilizou-se a avaliação de fatores de risco e a análise de sensibilidade e especificidade, comparando-se a acurácia do rastreamento de cardiopatia congênita por meio da ecografia obstétrica, da avaliação morfológica e da ecocardiografia fetal, considerando-se como significativo um p < 0,05. O referido estudo foi aprovado pelo Comitê de Ética em Pesquisa da Instituição. Resultados A análise de fatores de risco demonstra que 31,3% dos fetos com cardiopatia congênita poderiam ser identificados pela anamnese. As ecografias anteparto possuem sensibilidade de 97,7%, especificidade de 88,9% e acurácia de 93,0% no diagnóstico da cardiopatia congênita. Ao se analisar cada tipo de ecografia separadamente, encontrou-se sensibilidade de 29,3% para a ecografia obstétrica, de 54,3% para ecografia morfológica, e de 97,7% para ecocardiografia fetal. A ecocardiografia fetal definiu a cardiopatia fetal em 67,7% dos casos, a ecografia morfológica em 16,7%, e a ecografia obstétrica em 11,5%. Conclusão Demonstra-se uma elevada proporção de cardiopatia congênita em gestações sem fatores de risco para esse desfecho. Frente aos resultados desanimadores da ecografia obstétrica para a detecção de cardiopatias congênitas e na atual inviabilidade de rastreamento universal de cardiopatias congênitas por meio da ecocardiografia fetal, reforça-se a importância da ecografia morfológica fetal e sua realização por profissionais qualificados para esse fim de forma a permitir o manejo mais adequado destas gestações.


Subject(s)
Humans , Female , Pregnancy , Infant, Newborn , Echocardiography , Ultrasonography, Prenatal , Heart Defects, Congenital/diagnostic imaging , Reproducibility of Results , Retrospective Studies , Cohort Studies
5.
Rev. bras. ginecol. obstet ; 40(1): 43-46, Jan. 2018. tab
Article in English | LILACS | ID: biblio-1042312

ABSTRACT

Abstract Gestational syphilis is a prevalent disease in Brazil and other low and medium income countries. Desensitization to penicillin is recommended for pregnant women with syphilis who are allergic to β-lactams. This is a descriptive study utilizing outpatient medical records from 2011 to 2015 from a mother and child hospital that is part of the national healthcare system in the South of Brazil, which performs an average of 3,600 birth assistances per year. All cases of pregnant women with syphilis and presumptive diagnosis of β-lactam allergy during the study period were included. The patients referred for desensitization originated from the hospital prenatal care service, as well as from municipal/state antenatal care services. Oral desensitization was performed in the obstetric emergency room, and adult and pediatric intensive care units were available at all times. Ten patients underwent desensitization during the period of study. Personal history of urticaria was the most common reaction that demanded desensitization. All patients tolerated the procedure well, and showed no adverse reactions.We report a successful program of oral desensitization. None of the patients presented adverse reactions or complications, a fact that corroborates the feasibility and safety of the desensitization protocol. Oral administration of penicillin comes at a low cost, and optimizes the use of time and resources.


Resumo A sífilis gestacional é uma doença prevalente no Brasil e em outros países de baixa e média renda. A dessensibilização à penicilina é recomendada para mulheres grávidas com sífilis que são alérgicas a β-lactâmicos. Este é um estudo descritivo que utiliza registros médicos de 2011 a 2015 de um hospital público materno-fetal do Sul do Brasil com média de 3.600 partos anuais. Foram incluídos todos os casos de gestantes com sífilis e diagnóstico presuntivo de alergia a β-lactâmicos durante o período de estudo. As pacientes encaminhadas para dessensibilização originaram-se do serviço pré-natal hospitalar internamente, bem como dos serviços municipais e estaduais de atendimento pré-natal. A dessensibilização oral foi realizada na sala de emergência obstétrica, e a unidade de terapia intensiva estava disponível em todos os momentos para o atendimento de possíveis intercorrências. Dez pacientes foram submetidas à dessensibilização durante o período estudado. História pessoal de urticária foi a reação mais comum que exigiu dessensibilização à penicilina. Todas as pacientes toleraram bem o procedimento, e não mostraram reações adversas. Relatamos no presente manuscrito um programa bem-sucedido de dessensibilização oral à penicilina. Nenhuma das pacientes apresentou reações adversas ou complicações, corroborando a viabilidade e segurança do protocolo de dessensibilização. A administração oral de penicilina tem baixo custo, e otimiza o uso de tempo e recursos para o tratamento adequado de sífilis gestacional no cenário apresentado.


Subject(s)
Humans , Female , Pregnancy , Adult , Young Adult , Penicillins/administration & dosage , Pregnancy Complications, Infectious/drug therapy , Syphilis/drug therapy , Desensitization, Immunologic , Anti-Bacterial Agents/administration & dosage , Administration, Oral , Treatment Outcome
6.
RBM rev. bras. med ; 67(8)ago. 2010.
Article in Portuguese | LILACS | ID: lil-556297

ABSTRACT

A infecção do trato urinário (ITU) é uma complicação comum na gestação. Escherichia coli é o uropatógeno mais comum, encontrado em aproximadamente 80% das pacientes infectadas. Prematuridade, baixo peso ao nascer e até morte fetal podem estar associadas à ITU na gestação. O objetivo dessa atualização é discutir a antibioticoterapia para o tratamento da infecção do trato urinário baixo (cistite aguda) nos diferentes trimestres da gestação. A ampicilina é segura em qualquer etapa da gestação contudo a Escherichia coli apresenta altos índices de resistência a essa droga. Cefalexina parece ser uma droga segura em todos os estágios da gestação. Nitrofurantoína deve ser evitada no final da gestação pelo risco de hemólise neonatal. As complicações diminuem com investigação e tratamento adequados. O rastreamento precoce da bacteriúria na gestação, mesmo que assintomática, tem benefícios maternos e fetais.

7.
Article in Portuguese | LILACS | ID: lil-33782

ABSTRACT

O adenocarcinoma de células claras de vagina e cérvice é um câncer raro. Aproximadamente 2/3 destas pacientes têm história positiva de exposiçäo intra-uterina ao dietilestilbestrol. A maioria das pacientes säo jovens e têm estágios iniciais e säo tratados com sucesso pela cirurgia pélvica radical. Um cuidadoso programa de investigaçäo e tratamento é proposto pelos autores


Subject(s)
Child , Adolescent , Humans , Female , Adenocarcinoma/chemically induced , Uterine Cervical Neoplasms/chemically induced , Vaginal Neoplasms/chemically induced , Diethylstilbestrol/adverse effects
8.
Article in Portuguese | LILACS | ID: lil-33667

ABSTRACT

Realizou-se uma revisäo bibliográfica visando atualizaçäo na fisiopatologia e terapêutica da coagulopatia associada à morte fetal intraútero, com enfoque principal na heparinoterapia


Subject(s)
Pregnancy , Humans , Female , Blood Coagulation Disorders/complications , Fetal Death/etiology , Heparin/administration & dosage , Pregnancy Complications, Cardiovascular , Blood Coagulation Disorders/drug therapy
SELECTION OF CITATIONS
SEARCH DETAIL